About This Item
Empirical Formula (Hill Notation):
BaF2
CAS Number:
Molecular Weight:
175.32
NACRES:
NA.23
PubChem Substance ID:
UNSPSC Code:
12352302
EC Number:
232-108-0
MDL number:
Assay:
99.99% trace metals basis
Form:
solid
InChI key
OYLGJCQECKOTOL-UHFFFAOYSA-L
InChI
1S/Ba.2FH/h;2*1H/q+2;;/p-2
SMILES string
F[Ba]F
assay
99.99% trace metals basis
form
solid
reaction suitability
core: barium
impurities
≤150.0 ppm Trace Metal Analysis
bp
2260 °C (lit.)
density
4.89 g/mL at 25 °C (lit.)
Quality Level
Looking for similar products? Visit Product Comparison Guide
Features and Benefits
Primary glass modifier in fluorozirconate glasses.
signalword
Warning
hcodes
Hazard Classifications
Acute Tox. 4 Inhalation - Acute Tox. 4 Oral
Storage Class
13 - Non Combustible Solids
wgk
WGK 1
flash_point_f
Not applicable
flash_point_c
Not applicable
Regulatory Information
危险化学品
This item has
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
S Tavernier et al.
Medical progress through technology, 17(3-4), 237-241 (1991-01-01)
The work presented is part of a design study for a Positron Emission Tomograph (PET) scanner based on the use of BaF2 scintillator and photosensitive wire chambers. The detection efficiency for gamma radiation of 511 keV is found close to
Jian Ruan et al.
Optics express, 17(7), 5163-5169 (2009-04-01)
Bi-doped BaF(2) crystal was grown by the temperature gradient technique and its spectral properties were investigated. The absorption, emission and excitation spectra were measured at room temperature. Two broadband emissions centered at 1070 and 1500 nm were observed in Bi-doped
Dean C Sayle et al.
Physical chemistry chemical physics : PCCP, 7(1), 16-18 (2005-01-07)
We show, using simulation techniques, that the high ionic conductivity in BaF2/CaF2 heterolayers is because the interfaces reduce the activation energy barriers to mobility and increase the number of charge carriers.
C W van Eijk et al.
Medical progress through technology, 17(3-4), 243-247 (1991-01-01)
A detector has been developed for position sensitive registration of annihilation radiation. The 511 keV gamma rays are detected in a set of BaF2 scintillation crystals coupled to low pressure TMAE-filled photosensitive multi wire chambers. In a first experimental detector
W H Wong
Journal of nuclear medicine : official publication, Society of Nuclear Medicine, 29(3), 338-347 (1988-03-01)
Bismuth germanate (BGO) and barium fluoride (BaF2) scintillators are presently used in positron emission tomegraphy (PET) cameras. This study evaluates the important PET performance parameters of image resolution, true sensitivity, scatter background, accidental background, and realistic maximum radioactivity in the
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service