推荐产品
等级
ACS reagent
puriss. p.a.
质量水平
蒸汽密度
2.62 (vs air)
蒸汽压
0.08 mmHg ( 20 °C)
方案
≥99.5% (GC)
表单
viscous liquid
自燃温度
779 °F
保质期
3 yr
expl. lim.
12.5 %
杂质
≤0.003% free acid (as CH3COOH)
≤0.1% water
蒸发残留物
≤0.005%
灼烧残渣
<0.005% (as SO4)
折射率
n20/D 1.432 (lit.)
n20/D 1.433
沸点
187 °C (lit.)
mp
−60 °C (lit.)
密度
1.036 g/mL at 25 °C (lit.)
痕量阴离子
chloride (Cl-): ≤1 mg/kg
sulfate (SO42-): ≤20 mg/kg
痕量阳离子
Ca: ≤5 mg/kg
Cd: ≤1 mg/kg
Co: ≤1 mg/kg
Cr: ≤1 mg/kg
Cu: ≤1 mg/kg
Fe: ≤1 mg/kg
K: ≤20 mg/kg
Mg: ≤1 mg/kg
Mn: ≤1 mg/kg
Na: ≤20 mg/kg
Ni: ≤1 mg/kg
Pb: ≤1 mg/kg
Zn: ≤5 mg/kg
SMILES字符串
CC(O)CO
InChI
1S/C3H8O2/c1-3(5)2-4/h3-5H,2H2,1H3
InChI key
DNIAPMSPPWPWGF-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
一般描述
1,2-丙二醇是一种1,2-烷二醇。在Ru/C和Amberlyst离子交换树脂存在下,它可以通过甘油的氢解来获得。
应用
1,2-丙二醇(丙二醇)可用作人类胚胎和卵母细胞(人和小鼠)保存(通过冷却至零下温度)的冷冻保护剂。
储存分类代码
10 - Combustible liquids
WGK
WGK 1
闪点(°F)
219.2 °F - closed cup
闪点(°C)
104 °C - closed cup
个人防护装备
Eyeshields, Gloves
Journal of the American Chemical Society, 140(4), 1327-1336 (2018-01-10)
Supramolecular self-assembly at the solid-solid interface enables the deposition and monolayer formation of insoluble organic semiconductors under ambient conditions. The underlying process, termed as the organic solid-solid wetting deposition (OSWD), generates two-dimensional adsorbates directly from dispersed three-dimensional organic crystals. This
IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 64(3), 555-567 (2017-01-24)
Although high-frequency ultrasound imaging is gaining attention in various applications, hardly any ultrasound contrast agents (UCAs) dedicated to such frequencies (>15 MHz) are available for contrast-enhanced ultrasound (CEUS) imaging. Moreover, the composition of the limited commercially available UCAs for high-frequency
Tobacco induced diseases, 15, 14-14 (2017-02-28)
Despite the rising health and safety concerns of e-cigarettes, a universal e-cigarette testing method is still in its early developmental stage. The aim of this study was to develop an e-liquid Reference Material that can be used to improve accuracy
Autophagy, 12(2), 343-356 (2016-02-24)
Monitoring autophagic flux in vivo or in organs remains limited and the ideal methods relative to the techniques possible with cell culture may not exist. Recently, a few papers have demonstrated the feasibility of measuring autophagic flux in vivo by
Human reproduction (Oxford, England), 8(7), 1101-1109 (1993-07-01)
Human and mouse oocytes were cryopreserved by a slow freeze, rapid thaw method, using propanediol (PROH) as the cryoprotectant. A simulated cryopreservation was also included in the study to detect the level of damage attributable to the PROH alone. Comparison
Chromatograms
suitable for GCsuitable for GC我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门