跳转至内容
Merck
CN

HCVD2MAG-67K

MILLIPLEX® Human Cardiovascular Disease Panel

Configurable Human CVD 10-Plex Panel 2

登录 查看组织和合同定价。

关于此项目

UNSPSC Code:
12161503
NACRES:
NA.84
eCl@ss:
32161000
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助

产品名称

MILLIPLEX® Human Cardiovascular Disease Panel, Configurable Human CVD 10-Plex Panel 2

species reactivity

human

manufacturer/tradename

Milliplex®

Quality Level

packaging

1 ea of

assay range

accuracy: 88%
(Myoglobin)

accuracy: 90%
(P-selectin)

accuracy: 98%
(GDF-15)

standard curve range: 0.0005-2.5 ng/mL
(GDF-15)

standard curve range: 0.012-50 ng/mL
(Lipocalcin-2/NGAL)

standard curve range: 0.024-100 ng/mL
(Myoglobin & MPO)

standard curve range: 0.085-350 ng/mL
(sICAM-1)

standard curve range: 0.122-500 ng/mL
(sVCAM-1)

standard curve range: 0.244-1,000 ng/mL
(D-dimer, SAA & P-selectin)

standard curve range: 1.221-5,000 ng/mL
(ADAMTS 13)

inter-assay cv: <20%
intra-assay cv: <15%

technique(s)

multiplexing: suitable

input

serum plasma (Cell culture, cell culture supernatants)

detection method

fluorometric (Luminex® xMAP® technology)

shipped in

wet ice

storage temp.

2-8°C

Biochem/physiol Actions

Cross Reactivty
There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes in this panel.

Disclaimer

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
For research use only. Not for use in diagnostic procedures.Label License/Sticker for Assay Product:By opening the packaging containing this Assay Product (which contains fluorescently labeled microsphere beads authorized by Luminex Corporation) or using this Assay Product in any manner, you are consenting and agreeing to be bound by the End User Terms and Conditions and the End User License Agreement available at http://support.diasorin.com/end-user-terms-and-conditions/. If you do not agree to all of the terms and conditions, you must promptly return this Assay Product for a full refund prior to using it in any manner.
For research use only. Not for use in diagnostic procedures.Label License/Sticker for Assay Product:By opening the packaging containing this Assay Product (which contains fluorescently labeled microsphere beads authorized by Luminex Corporation) or using this Assay Product in any manner, you are consenting and agreeing to be bound by the End User Terms and Conditions and the End User License Agreement available at http://support.diasorin.com/end-user-terms-and-conditions/. If you do not agree to all of the terms and conditions, you must promptly return this Assay Product for a full refund prior to using it in any manner.
For research use only. Not for use in diagnostic procedures.Label License/Sticker for Assay Product:By opening the packaging containing this Assay Product (which contains fluorescently labeled microsphere beads authorized by Luminex Corporation) or using this Assay Product in any manner, you are consenting and agreeing to be bound by the End User Terms and Conditions and the End User License Agreement available at http://support.diasorin.com/end-user-terms-and-conditions/. If you do not agree to all of the terms and conditions, you must promptly return this Assay Product for a full refund prior to using it in any manner.

General description

Cardiovascular disease, particularly atherosclerotic vascular disease, is a leading cause of global mortality, accounting for 30% of all global deaths (WHO, 2010). Inflammatory mechanisms play a vital role in the initiation, maintenance, and progression of vascular disease with a strong correlation between inflammatory markers and prognosis in acute and chronic coronary artery disease. Numerous studies have demonstrated an association of obesity and diabetes with cardiovascular risk factors.

MILLIPLEX® Human Cardiovascular Disease (CVD) Panel 2 is a 10-plex kit to be used for the simultaneous quantification of any or all of the following analytes in human serum, plasma and tissue/cell lysate and culture supernatant samples: Adamts13, D-dimer, GDF-15, Myoglobin, sICAM-1, MPO, P-selectin, Lipocalin-2/NGAL, sVCAM-1 and SAA. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.

The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.

Panel Type: Cardiovascular
Cardiovascular disease is closely linked to inflammation, endothelial dysfunction, oxidative stress, and coagulation abnormalities. This set of biomarkers—ADAMTS13, D-dimer S, GDF15, sICAM-1, Myeloperoxidase (MPO), Myoglobin, NGAL/Lipocalin-2, sP-Selectin, Serum Amyloid A, and sVCAM-1—captures key indicators of vascular injury, immune activation, and thrombotic risk. These analytes are widely studied in the context of atherosclerosis, acute coronary syndromes, and systemic inflammation, making them highly relevant for translational and clinical cardiovascular research.

Other Notes

Sensitivity: See kit protocol for individual analytes sensitive’s.

Legal Information

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

Application

MILLIPLEX® Qualified assays undergo rigorous assay development, verification, and Quality Control testing to achieve optimal performance. Simultaneously analyze up to 10 analytes in human serum, plasma, or cell culture supernatants.Analytes included: ADAMTS13, D-dimer S, GDF15, sICAM-1, Myeloperoxidase (MPO), Myoglobin, NGAL/Lipocalin-2, sP-Selectin, Serum Amyloid A, sVCAM-1Note: D-Dimer cannot be measured in plasma samples.Assay Characteristics: Refer to assay protocol for details on cross-reactivity, sensitivity, precision, and accuracy.

Features and Benefits

Features:
  • Targets biomarkers involved in vascular inflammation, endothelial activation, and coagulation
  • Includes 10 analytes relevant to cardiovascular risk, oxidative stress, and immune response
  • Multiplex format enables simultaneous detection from minimal sample volume
  • Compatible with human serum and plasma samples
  • Designed for research in atherosclerosis, thrombosis, acute coronary syndromes, and systemic inflammation
Benefits:
  • Provides a comprehensive profile of cardiovascular and inflammatory biomarkers
  • Supports investigation of vascular injury, immune activation, and thrombotic mechanisms
  • Facilitates evaluation of therapeutic interventions and biomarker-based risk assessment
  • Enables high-throughput analysis with reduced sample and reagent use
  • Delivers reproducible, sensitive results for translational and clinical research

pictograms

Exclamation markEnvironment

signalword

Warning

Hazard Classifications

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Irrit. 2 - Skin Sens. 1 - STOT SE 3

target_organs

Respiratory system

存储类别

10 - Combustible liquids

wgk

WGK 3

法规信息

新产品
此项目有

分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Rebeca Quirós-Fernández et al.
Nutrients, 11(3) (2019-03-20)
Hydroxytyrosol (HT) and Punicalagin (PC) exert cardioprotective and anti-atherosclerotic effects. This study evaluates the effect of oral supplementation with HT and PC (SAx) on early atherosclerosis markers in middle-aged, seemingly healthy adults. A randomized, double-blinded, placebo-controlled, crossover trial was performed
Kiara C S Zapponi et al.
Journal of thrombosis and thrombolysis (2021-08-28)
Neutrophil activation and neutrophil extracellular traps (NETs) have been associated with the pathogenesis of venous thromboembolism (VTE). Considering VTE-associated chronic sequelae, which suggest that some pathological mechanisms remain after the acute episode, we investigated whether neutrophil activation is increased in
Estefania Simoes et al.
International journal of obesity (2005), 45(4), 879-887 (2021-02-03)
Childhood overweight and obesity are a global concern, with prevalence rising dramatically over the last decades. The condition is caused by an increase in energy intake and reduction of physical activity, leading to excessive fat accumulation, followed by systemic chronic
Lilliam Rocha-Penha et al.
Hypertension (Dallas, Tex. : 1979), 69(6), 1173-1180 (2017-05-04)
Elevated levels of myeloperoxidase have been demonstrated in women with preeclampsia where it may contribute to endothelial dysfunction mediated, in part, by nitric oxide impairment. In this study, we investigated myeloperoxidase in hypertensive disorders of pregnancy and its contribution to
Alberto Soriano-Maldonado et al.
Journal of clinical medicine, 7(12) (2018-11-28)
This study assessed the effect of 12-week aerobic exercise on arterial stiffness (primary outcome), inflammation, oxidative stress, and cardiorespiratory fitness (secondary outcomes) in women with systemic lupus erythematosus (SLE). In a non-randomized clinical trial, 58 women with SLE were assigned

相关内容

Learn about biomarkers of cardiovascular disease (CVD) and discover how multiplex CVD panels, such as MILLIPLEX® multiplex assays, are being used to increase the efficiency of biomarker discovery for CVD research.

Uncover tips and tricks to multiplexing in this guide from the experts. Learn how you can enhance the power of your research with MILLIPLEX® multiplexing, including industry guidance for immunoassays, multiplexing tips, one-day MILLIPLEX® multiplex assays for limited lab time, and more.

查看所有结果

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系客户支持