Skip to Content
Merck
CN
  • Rapid screening of oleuropein from olive leaves using matrix solid-phase dispersion and high-performance liquid chromatography.

Rapid screening of oleuropein from olive leaves using matrix solid-phase dispersion and high-performance liquid chromatography.

Journal of AOAC International (2014-08-26)
Marzieh Rashidipour, Rouhollah Heydari, Alireza Feizbakhsh, Payman Hashemi
ABSTRACT

Matrix solid-phase dispersion (MSPD) methodology as a quick and easy extraction method has been developed to extract oleuropein from Olea europaea leaves. This method has been compared with conventional maceration and Soxhlet extraction (SOXE) methods. Variables affecting MSPD, such as the sorbent material, the ratio of sample to sorbent material, elution solvent, and volume of the elution solvent, have been fully evaluated and optimized. Oleuropein was successfully extracted by silica sorbent with 350 microL of dichloromethane-methanol (70 + 30, v/v) as the elution solvent. The calibration curve showed good linearity (r2 = 0.9985) and precision (RSD <4.5%) in the concentration range of 0.5-100 microg/mL for oleuropein. The LOD and LOQ were 0.14 and 0.5 microg/mL, respectively. The recoveries were in the range of 88.0-94.0% with RSD values ranging from 6.0 to 9.8%. The extraction yields obtained by the MSPD method were comparable with those obtained by the maceration and SOXE methods. The reported MSPD extraction method was revealed to be eco-friendly, simpler, and faster than conventional methods used to quantify oleuropein in O. europaea leaves.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Acetone, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acetone, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Acetone, ≥99%, FCC, FG
Sigma-Aldrich
Acetone, natural, ≥97%
Sigma-Aldrich
Methanol, suitable for NMR (reference standard)
Sigma-Aldrich
Phosphoric acid solution, suitable for NMR (reference standard), 85% in D2O (99.9 atom % D), NMR tube size 4.2 mm × 8 in. , WGS-5BL Coaxial NMR tube
Sigma-Aldrich
Phosphoric acid solution, suitable for NMR (reference standard), 85% in D2O (99.9 atom % D), NMR tube size 5 mm × 8 in.
Sigma-Aldrich
Phosphoric acid solution, suitable for NMR (reference standard), 85% in D2O (99.9 atom % D), NMR tube size 3 mm × 8 in.
Supelco
Acetone, analytical standard
Supelco
Methanol, analytical standard
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Methanol, purification grade, 99.8%
Supelco
Acetone, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Ethanol solution, certified reference material, 2000 μg/mL in methanol
Supelco
Ethanol standards 10% (v/v), 10 % (v/v) in H2O, analytical standard
Supelco
1,4-Dioxane, analytical standard
Sigma-Aldrich
Phosphoric acid solution, 85 wt. % in H2O, FCC, FG
Sigma-Aldrich
Acetone, suitable for HPLC, ≥99.8%
Supelco
1,4-Dioxane, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Dehydrated Alcohol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Ethanol Fixative 80% v/v, suitable for fixing solution (blood films)
Sigma-Aldrich
1,4-Dioxane, anhydrous, 99.8%, contains <=25 ppm BHT as stabilizer
Sigma-Aldrich
1,4-Dioxane, suitable for HPLC, ≥99.5%
Sigma-Aldrich
1,4-Dioxane, ReagentPlus®, ≥99%, contains ≤25 ppm BHT as stabilizer
Sigma-Aldrich
1,4-Dioxane, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.5% (GC)
Sigma-Aldrich
1,4-Dioxane, ACS reagent, ≥99.0%, contains <=25 ppm BHT as stabilizer