Skip to Content

尊敬的客户:

目前国际形势复杂多变,关税政策尚不明朗,这可能对我们的产品价格产生一定影响。在此情况下,我们希望就订单事宜与您进行友好沟通。

基于当前的不确定性,如果您选择在此期间下单,我们将保留根据实际情况调整价格的权利。同时,我们也理解市场变化可能给您带来的困扰,因此如果在订单实际发货前因关税政策变动导致价格出现较大波动,默克将与您进行协商讨论并视情况对订单进行调整或取消。

关于应对近期政策变化的重要更新,请点击此处查看详情。

Merck
CN
  • A simple and rapid extraction method for sensitive determination of perfluoroalkyl substances in blood serum suitable for exposure evaluation.

A simple and rapid extraction method for sensitive determination of perfluoroalkyl substances in blood serum suitable for exposure evaluation.

Journal of chromatography. A (2012-03-17)
Noelia Luque, Ana Ballesteros-Gómez, Stefan van Leeuwen, Soledad Rubio
ABSTRACT

In this work, we propose a microextraction method based on a new supramolecular solvent (SUPRAS) made up of reverse aggregates of hexanoic acid, combined with liquid chromatography/triple quadrupole mass spectrometry (LC/QQQ MS-MS) for the determination of the perfluoroalkyl substances (PFASs) in blood serum. A SUPRAS is a nano-structured liquid made up of surfactant aggregates synthesized through a self-assembly process. The method involved the acidification of 765 μL of blood serum (600 μmol of hydrochloric acid per mL of serum) followed by the addition of hexanoic acid (97 μL) and tetrahydrofuran (THF) (600 μL), conditions under which the supramolecular solvent (∼360 μL) formed in situ after vortex-shaking and centrifugation. Parameters affecting extraction efficiency and concentration factors were studied. The overall sample treatment took only 20 min and several samples (20-30) can be simultaneously analyzed using conventional lab equipments, making additional investments unnecessary. Recoveries for the internal standards in samples ranged from 75 to 89% with relative standard deviations between 1 and 15%. Calibration was based on the use of internal standards. The method was very sensitive with detection limits ranging from 2 to 20 pg mL(-1) for PFASs. The approach developed was successfully applied to the determination of PFASs in different blood serum samples. The concentration of PFASs found in samples of animal origin ranged between 17 and 197.3 pg mL(-1) and between 84 and 5168 pg mL(-1) in samples of human origin. Both the analytical and operational features of this method make it suitable for the evaluation of exposure to PFASs.

MATERIALS
Product Number
Brand
Product Description

Supelco
Hexanoic acid, analytical standard
Sign Into View Organizational & Contract Pricing
SKUPack SizeAvailabilityPriceQuantity
5 mL
Available to ship on 2025年4月18日
Details...
¥1,380.04
Sigma-Aldrich
Hexanoic acid, purum, ≥98.0% (GC)
Sign Into View Organizational & Contract Pricing
SKUPack SizeAvailabilityPriceQuantity
100 mL
Available to ship on 2025年4月18日
Details...
¥422.63
500 mL
Please contact Customer Service for Availability
¥627.84
Sigma-Aldrich
Hexanoic acid, ≥99%
Sign Into View Organizational & Contract Pricing
SKUPack SizeAvailabilityPriceQuantity
2.5 g
Available to ship on 2025年4月18日
Details...
¥196.28
100 g
Available to ship on 2025年4月18日
Details...
¥464.01
¥278.41
500 g
Please contact Customer Service for Availability
¥609.53
Sigma-Aldrich
Hexanoic acid, ≥98%, FCC, FG
Sign Into View Organizational & Contract Pricing
SKUPack SizeAvailabilityPriceQuantity
Please contact Customer Service for Availability
¥404.65
1 kg
Please contact Customer Service for Availability
¥626.36
5 kg
Please contact Customer Service for Availability
¥2,536.49
25 kg
Estimated to ship on 2025年6月25日
Details...
¥3,814.45
Sigma-Aldrich
Sodium hexanoate, 99-100%
Sign Into View Organizational & Contract Pricing
SKUPack SizeAvailabilityPriceQuantity
10 g
Available to ship on 2025年4月18日
Details...
¥797.35
25 g
Please contact Customer Service for Availability
¥1,786.93