Skip to Content

尊敬的客户:

目前国际形势复杂多变,关税政策尚不明朗,这可能对我们的产品价格产生一定影响。在此情况下,我们希望就订单事宜与您进行友好沟通。

基于当前的不确定性,如果您选择在此期间下单,我们将保留根据实际情况调整价格的权利。同时,我们也理解市场变化可能给您带来的困扰,因此如果在订单实际发货前因关税政策变动导致价格出现较大波动,默克将与您进行协商讨论并视情况对订单进行调整或取消。

We are planning system maintenance between Friday, Apr 18 at 9:00 PM CDT and Saturday, Apr 19 at 9:00 AM CDT. This will impact both web and offline transactions, including online orders, quotes, price and availability checks, and order status inquiries. We apologize for any inconvenience.

关于应对近期政策变化的重要更新,请点击此处查看详情。

Merck
CN

Biological Monitoring of Metal Ions Released from Hip Prostheses.

International journal of environmental research and public health (2020-05-10)
Annamaria Nicolli, Andrea Trevisan, Isabella Bortoletti, Assunta Pozzuoli, Pietro Ruggieri, Andrea Martinelli, Alberto Gambalunga, Mariella Carrieri
ABSTRACT

The aim of this study was to evaluate the levels of As, Be, Bi, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Se, Tl, V, and Zn, by inductively coupled plasma-mass spectrometry (ICP-MS) in the urine of two groups of patients with two different types of metal-on-metal (MoM) total hip prostheses (ASR DePuy®, group A, 25 patients; total Met-Met System Lima®, group B, 28 patients). The determination of metals reflected a steady-state release (group A: 9 years after surgery and group B: 6 years after surgery). The results obtained confirmed the increase of Co and Cr urinary levels in both group when compared with the reference values for the general population adopted by the Italian Society of Reference Values (SIVR). In particular, Co and Cr levels exceeded the threshold values in urine, respectively, of 30 μg and 21 µg, adjusted to creatinine based on the threshold in whole blood of 7 μg/L proposed by the Medicines and Healthcare Products Regulatory Agency (MHRA). Regarding the other investigated metals, significantly higher values were found in Group A than in Group B. These differences could be due to the type of hip prosthesis implanted, the longer period of time since the implantation, as well as many other factors such as diet, age, drug consumption, physical activity, or presence of dental fillings. The continuous monitoring over the years of metal concentrations in patients carrying a prosthesis could be useful to better identify the sources of these metals.

MATERIALS
Product Number
Brand
Product Description

Milli-Q
Milli-Q® IQ 7010 Ultrapure and Pure Water Purification System, Produces ultrapure (Type 1) water and pure (Type 2) water with a production flow rate of 10 L/hr from tap water feed.
Pricing and availability is not currently available.
Milli-Q
Milli-Q® IQ 7003 Ultrapure and Pure Water Purification System, Produces ultrapure (Type 1) water and pure (Type 2) water with a production flow rate of 3 L/hr from tap water feed
Pricing and availability is not currently available.
Milli-Q
Milli-Q® IQ 7005 Ultrapure and Pure Water Purification System, Produces ultrapure (Type 1) water and pure (Type 2) water with a production flow rate of 5 L/hr from tap water feed.
Pricing and availability is not currently available.
Milli-Q
Milli-Q® IQ 7015 Ultrapure and Pure Water Purification System, Produces ultrapure (Type 1) water and pure (Type 2) water with a production flow rate of 15 L/hr from tap water feed.
Pricing and availability is not currently available.