HLPPMAG-57K
MILLIPLEX® Human Liver Protein Magnetic Bead Panel - Metabolism Multiplex Assay
The Human Liver Protein Panel, using the Luminex xMAP technology, enables the simultaneous analysis of 9 liver protein biomarkers in human serum, plasma and tissue/cell culture samples.
About This Item
Quality Level
species reactivity
human
manufacturer/tradename
Milliplex®
assay range
accuracy: 100.2%
(HGF)
accuracy: 93.7%
(ANGPTL3)
accuracy: 94.2%
(AFP)
accuracy: 96.6%
(FGF-23)
accuracy: 96.8%
(ANGPTL4)
accuracy: 98.8%
(FGF-21)
sensitivity: 0.004 ng/mL
(MinDC+2SD; FGF-21)
sensitivity: 0.014 ng/mL
(MinDC+2SD; FGF-23)
sensitivity: 0.018 ng/mL
(MinDC+2SD; HGF)
sensitivity: 0.054 ng/mL
(MinDC+2SD; FGF-19)
sensitivity: 0.144 ng/mL
(MinDC+2SD; AFP)
sensitivity: 0.218 ng/mL
(MinDC+2SD; FABP1)
sensitivity: 0.725 ng/mL
(MinDC+2SD; ANGPTL3)
sensitivity: 0.847 ng/mL
(MinDC+2SD; ANGPTL6)
sensitivity: 2.150 ng/mL
(MinDC+2SD; ANGPTL4)
standard curve range: 0.01-10 ng/mL
(FGF-21)
standard curve range: 0.04-30 ng/mL
(FGF-23)
standard curve range: 0.07-50 ng/mL
(HGF)
standard curve range: 0.14-100 ng/mL
(AFP)
standard curve range: 0.14-100 ng/mL
(FGF-19)
standard curve range: 0.27-200 ng/mL
(FABP1)
standard curve range: 0.69-500 ng/mL
(ANGPTL3)
standard curve range: 1.37-1000 ng/mL
(ANGPTL6/AGF)
standard curve range: 5.49-4000 ng/mL
(ANGPTL4)
inter-assay cv: <20%
intra-assay cv: <10%
(AFP)
inter-assay cv: <20%
intra-assay cv: <10%
(ANGPTL3)
inter-assay cv: <20%
intra-assay cv: <10%
(ANGPTL4)
inter-assay cv: <20%
intra-assay cv: <10%
(ANGPTL6/AGF)
inter-assay cv: <20%
intra-assay cv: <10%
(FABP1)
inter-assay cv: <20%
intra-assay cv: <10%
(FGF-19)
inter-assay cv: <20%
intra-assay cv: <10%
(FGF-21)
inter-assay cv: <20%
intra-assay cv: <10%
(FGF-23)
inter-assay cv: <20%
intra-assay cv: <10%
(HGF)
technique(s)
multiplexing: suitable
detection method
fluorometric (Luminex xMAP)
shipped in
wet ice
Related Categories
General description
MILLIPLEX® Human Liver Protein Panel is a 9-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum, plasma and tissue/cell culture samples: AFP, ANGPTL3, ANGPTL4, ANGPTL6/AGF, FABP1/L-FABP, FGF-19, FGF-21, FGF-23 and HGF.
NOTE: When assaying ANGPTL6/AGF it is recommended that serum samples be used.
This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Metabolism
Specificity
The ANGPTL6 standard had cross reactivity with the ANGPTL4 assay of less than 2%. For all other analytes, there was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes in this panel.
Application
- Analytes: α-Fetoprotein (AFP), ANGPTL3, ANGPTL4, ANGPTL6 (AGF), FABP1 (L-FABP), FGF-19, FGF-21, FGF-23, HGF
- Recommended Sample Type: Human serum, plasma, and cell/tissue culture supernatants or lysates
- NOTE: Serum samples are recommended when measuring ANGPTL6/AGF
- Recommended Sample Dilution: 12.5 μL per well of 1:2 diluted serum or plasma. Cell/tissue culture samples may be used undiluted or appropriately diluted in control medium.
- Assay Run Time: Overnight (16-18 hours) at 2-8°C is recommended for optimal sensitivity. 2 hours at room temperature (20-25° C) may also be used.
- Research Category: Metabolism
- Research Subcategory: Metabolic Disorders
Features and Benefits
Packaging
Storage and Stability
Other Notes
Legal Information
Disclaimer
Signal Word
Danger
Hazard Statements
Precautionary Statements
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Skin Sens. 1
Storage Class Code
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Regulatory Information
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Related Content
UnEnhance research with MILLIPLEX® multiplexing tips, industry guidance, and one-day assays for limited lab time.
Multiplex immunoassays, such as MILLIPLEX® multiplex metabolic assays, are critical in metabolic syndrome research because they provide a full picture of the different conditions related to it, like diabetes and obesity, as well as save time and sample volume.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service