质量水平
种属反应性
human
制造商/商品名称
Milliplex®
assay range
accuracy: 100%
(Apelin)
accuracy: 92%
(IL-15)
accuracy: 96%
(FSTL-1)
accuracy: 97%
(LIF)
accuracy: 98%
(Oncostatin M (OSM))
sensitivity: 0.9 pg/mL
(MinDC+2SD; IL-6)
sensitivity: 14 pg/mL
(MinDC+2SD; FGF-21)
sensitivity: 259 pg/mL
(MinDC+2SD; Myostatin/GDF8)
sensitivity: 281 pg/mL
(MinDC+2SD; Irisin)
sensitivity: 4 pg/mL
(MinDC+2SD; LIF)
sensitivity: 40 pg/mL
(MinDC+2SD; Fractalkine/CX3CL1)
sensitivity: 5 pg/mL
(MinDC+2SD; IL-15)
sensitivity: 59 pg/mL
(MinDC+2SD; Osteocrin/Musclin)
sensitivity: 6 pg/mL
(MinDC+2SD; Oncostatin M (OSM))
sensitivity: 64 pg/mL
(MinDC+2SD; Apelin)
sensitivity: 7.5 ng/mL
(MinDC+2SD; Osteonectin (SPARC))
sensitivity: 737 pg/mL
(MinDC+2SD; Follistatin-like Protein 1 (FSTL1))
sensitivity: 815 pg/mL
(MinDC+2SD; Erythropoietin (EPO))
sensitivity: 9 pg/mL
(MinDC+2SD; BDNF)
sensitivity: 9.8 pg/mL
(MinDC+2SD; FABP3)
standard curve range: 0.6-2,400 pg/mL
(IL-6)
standard curve range: 10-40,000 pg/mL
(LIF)
standard curve range: 122-500,000 pg/mL
(Apelin)
standard curve range: 2-10,000 pg/mL
(BDNF)
standard curve range: 2-10,000 pg/mL
(IL-15)
standard curve range: 2-6,000 pg/mL
(Oncostatin M (OSM))
standard curve range: 24-100,000 pg/mL
(FABP3)
standard curve range: 244-1,000,000 pg/mL
(Erythropoietin (EPO))
standard curve range: 244-1,000,000 pg/mL
(Irisin)
standard curve range: 488-2,000,000 pg/mL
(Follistatin-like Protein 1 (FSTL1))
standard curve range: 488-2,000,000 pg/mL
(Myostatin/GDF8)
standard curve range: 49-200,000 pg/mL
(Fractalkine/CX3CL1)
standard curve range: 49-200,000 pg/mL
(Osteocrin/Musclin)
standard curve range: 5-20,000 pg/mL
(FGF-21)
standard curve range: 7-30,000 ng/mL
(Osteonectin (SPARC))
inter-assay cv: <15%
intra-assay cv: <10%
(Apelin)
inter-assay cv: <15%
intra-assay cv: <10%
(BDNF)
inter-assay cv: <15%
intra-assay cv: <10%
(Erythropoietin (EPO))
inter-assay cv: <15%
intra-assay cv: <10%
(FABP3)
inter-assay cv: <15%
intra-assay cv: <10%
(FGF-21)
inter-assay cv: <15%
intra-assay cv: <10%
(Follistatin-like Protein 1 (FSTL1))
inter-assay cv: <15%
intra-assay cv: <10%
(Fractalkine/CX3CL1)
inter-assay cv: <15%
intra-assay cv: <10%
(IL-15)
inter-assay cv: <15%
intra-assay cv: <10%
(IL-6)
inter-assay cv: <15%
intra-assay cv: <10%
(Irisin)
inter-assay cv: <15%
intra-assay cv: <10%
(LIF)
inter-assay cv: <15%
intra-assay cv: <10%
(Myostatin/GDF8)
inter-assay cv: <15%
intra-assay cv: <10%
(Oncostatin M (OSM))
inter-assay cv: <15%
intra-assay cv: <10%
(Osteocrin/Musclin)
inter-assay cv: <20%
intra-assay cv: <10%
(Osteonectin (SPARC))
技术
multiplexing: suitable
检测方法
fluorometric (Luminex xMAP)
运输
wet ice
一般描述
MILLIPLEX®人肌动蛋白面板是一种15重试剂盒,用于同时定量人血清、血浆和细胞/组织培养上清液样品中以下任何或所有分析物:Fractalkine/CX3CL1,BDNF,制瘤素M(OSM),骨连接蛋白(SPARC),LIF,FGF-21,促红细胞生成素(EPO),IL-15,IL-6,Apelin,Myostatin/GDF8,鸢尾素,Osteocrin/Musclin,FABP3和卵泡抑素样蛋白(FSTL 1)。该试剂盒采用96孔板,包含冻干标准混合物、两个内部检测质控品,可最多可测定38份样本,重复两次。
Luminex® xMAP®平台使用磁珠免疫分析格式,以实现理想的速度和灵敏度,同时定量多种分析物,从而显著提高生产力,同时节省宝贵的样本量。
面板类型:代谢
应用
- 分析物:Apelin(APLN)、脑源性神经营养因子(BDNF)、促红细胞生成素(EPO)、脂肪酸结合蛋白3(FABP3)、成纤维细胞生长因子21(FGF21)、Fractalkine(CX3CL1)、卵泡抑素样1蛋白(FSTL-1)、IL-6、IL-15、鸢尾素、白血病抑制性因子(LIF)、肌肉生长抑制素(MSTN/GDF8)、制瘤素M(OSM)、骨调节素(OSTN/Musclin)、骨连接蛋白(SPARC)
- 推荐的样品类型:人血清、血浆和细胞/组织培养上清液或裂解液
- 注释:大量的BDNF储存在循环的血小板中,随后在血小板活化后释放。因此,贫血小板血浆对于确保BDNF循环水平的准确测量至关重要。
- 推荐的样品稀释度:每孔25 μL 1:2稀释的血清或血浆。细胞/组织培养样品可以在未稀释或适当稀释的对照培养基中运行。
- 分析运行时间:在2-8℃下过夜(16-18小时)或在室温(20-25℃)下2小时。
- 研究类别:骨
- 研究子类别:代谢
特点和优势
其他说明
法律信息
警示用语:
Danger
危险分类
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Irrit. 2 - Skin Sens. 1 - STOT RE 2
靶器官
Respiratory Tract
储存分类代码
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
法规信息
相关内容
Myokine analysis with multiplex immunoassays, such as the MILLIPLEX® Human Myokine Panel, allow researchers to simultaneously measure multiple muscle-secreted factors, providing more insights into related diseases.
Simplify protein biomarker discovery with the MILLIPLEX® PLEXpedition 115-Plex Multiplex Screening Panel. Effortlessly screen cytokines and other markers with Luminex® technology.
Multiplex immunoassays, such as MILLIPLEX® multiplex metabolic assays, are critical in metabolic syndrome research because they provide a full picture of the different conditions related to it, like diabetes and obesity, as well as save time and sample volume.
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门