If you decide to place an order during this period, we reserve the right to adjust the price based on the evolving situation. We understand that market changes may cause inconvenience. We will negotiate with you if there’s a significant price fluctuation due to tariff policy changes before the order’s actual delivery, and in such cases we may adjust or cancel the order as necessary.

Merck
CN
HomePhotometry & ReflectometryAnalytical Method: Analytical Quality Assurance, Standard for Chlorine Dioxide

Analytical Method: Analytical Quality Assurance, Standard for Chlorine Dioxide

Reagents:

Cat.No. 102404 Potassium iodate, volumetric standard
Cat.No. 105043 Potassium iodide for analysis
Cat.No. 109072 Sulfuric acid 0.5 mol/L
Cat.No. 109136 Sodium hydroxide solution 2 mol/L
Cat.No. 116754 Water for analysis

Preparation of a KlO3 Stock Solution:

Dissolve 1.005 g of KlO3 in 250 mL of distilled water in a calibrated or conformity-checked 1000-mL volumetric flask. Subsequently make up to the mark with distilled water.

Preparation of a KlO3/Kl Standard Solution:

Transfer 10.5 mL of the KlO3 stock solution to a calibrated or conformity-checked 1000-mL volumetric flask, add approx. 1.0 g of Kl and make up to the mark with distilled water. 1 mL of this solution is equivalent to 0.020 mg of chlorine dioxide.

Preparation of the Chlorine Dioxide Standard Solution:

Pipette 10 mL KlO3/Kl standard solution into a calibrated or conformity-checked 100-mL volumetric flask, add
2.0 mL of H2SO4 0.5 mol/L, leave to stand for 1 min, and then add NaOH 2 mol/L dropwise (approx. 1 mL) until the solution just loses its color. Subsequently make up the solution to the mark with distilled water. The concentration of the solution is 2.00 mg/L chlorine dioxide.

Stability:

The KlO3 stock solution remains stable for 4 weeks when stored in a cool place. The KlO3/Kl standard solution can be used for 5 hours when stored in a cool place. The dilute chlorine dioxide standard solution is not stable and must be used immediately.

For use with test kits: Measuring Range
in mg/L

118754

MColortestTM Chlorine dioxide Test

0.020 - 0.55 ClO2

118756

MColortestTM Chlorine dioxide Test

0.50 - 28 ClO2

118757

MColortestTM Chlorine dioxide Test refill pack for 118756

100608

Spectroquant® Chlorine dioxide Test

0.020 - 10.00 ClO2